The gateway needs to be connected to a PC first not to local network, as it's set to DHCP server by default, web-browse the device using its default address http://192.168.2.1 To enable WAN configurations which will allow remote access to the gateway, we follow below steps: 1-Setup--> Network Interf...

27 Jul 2020 By: Kate Figg

The gateway needs to be connected to a PC first not to local network, as it's set to DHCP server by default, web-browse the device using its default address http://192.168.2.1

To enable WAN configurations which will allow remote access to the gateway, we follow below steps:

1-Setup--> Network Interfaces --> click on the pencil to edit etho interface--> Direction --> set to WAN, and then IPv4 settings--> Mode-->set to DHCP client.
2-Firewall--> Input Filter Rules--> Add Rule--> Add two Webaccess, Source: any, Destination: 443 & 80 which are for HTTPs and HTTP.
3-from Administration --> Access Configuration--> tick all HTTP Redirect to HTTPs boxes, and tick the Via WAN box in HTTPs.

4-Save and Restart, and wait till the gateway finishes rebooting.